WORKING / DEPLOYED
Sample data

Impact

Evidence

Evidence chain for each verified sample record. Data, action, before/after and verification status.

SAMPLE DATA MODE

  1. 01 Data

    What is happening?

  2. 02 Analysis

    What is wrong and why?

  3. 03 Solution

    What should be done?

  4. 04 Impact

    What changed and can we prove it?

Data context

Organisation
NEXUS Reference Portfolio
Site
Portfolio · 4 Reference Facilities
Building
4 Reference Facilities
Location
Dubai, UAE
Asset
Portfolio view
Data source / Meter
NEXUS Simulator
Metric
Energy · Water
Unit
kW · L/hr
Resolution
Site to asset / zone
Data quality
HIGH — SAMPLE
Integration
Simulated — No live BMS / IoT
Data mode
Sample

NX-000192

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Cooling schedule corrected

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

Cooling schedule corrected

Business Bay HQ · Smart Meter SM2044

  1. 01 Before

    178 kWh/day

  2. 02 Action

    Cooling schedule corrected

  3. 03 After

    149 kWh/day

  4. 04 Verified result

    AED 4,760

Reduction
10,585 kWh avoided · 1.70 tCO₂e avoided
Financial impact
AED 4,760
Evidence
Smart Meter SM2044
Confidence
93%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
CH-Z4 — Zone 4 cooling plant
Source ID
SM2044 · Floor energy meter
Source type
SMART METER / SIMULATED METER
Data quality
HIGH — SAMPLE
Detection resolution
ASSET / ZONE
Data limitation
Sample stream only. No live BMS or IoT connectivity.
Baseline window
7-day window
Intervention
Cooling schedule corrected
Measurement window
7-day window
Before
178 kWh/day
After
149 kWh/day
Unit
Demand · kWh/day
Verification status
VERIFIED
Evidence
Smart Meter SM2044

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 7-day verified meter window. Demo synthetic. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency / asset-level M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Zone 4 cooling 24.5% above expected.

  2. 02

    ANALYTICS

    Baseline locked at 178 kWh/day from SM2044.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. NEXUS recommended 15:00–17:30 setback.

  4. 04

    RECOMMENDATION

    NEXUS recommended 15:00–17:30 setback.

  5. 05

    APPROVAL

    Operator approved. Execution pending BMS write.

  6. 06

    ACTION

    Schedule corrected on-site by facilities.

  7. 07

    MEASUREMENT

    Seven-day mean 149 kWh/day.

  8. 08

    VERIFICATION

    Window closed. 29 kWh/day avoided holds.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
CH-Z4 — Zone 4 cooling plant
Source ID
SM2044 · Floor energy meter
Source type
SMART METER / SIMULATED METER
Metric
Demand · kWh/day
Data quality
HIGH — SAMPLE
Detection resolution
ASSET / ZONE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Energy Baseline Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

NX-000188

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Night-flush valve isolated

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

Night-flush valve isolated

JLT Operations Centre · Sub-meter SM0881

  1. 01 Before

    1,960 L/hr overnight

  2. 02 Action

    Night-flush valve isolated

  3. 03 After

    410 L/hr overnight

  4. 04 Verified result

    AED 9,840

Reduction
1.24M L avoided · 0.42 tCO₂e avoided
Financial impact
AED 9,840
Evidence
Sub-meter SM0881
Confidence
95%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
SITE LEVEL
Source ID
SM0881 · Overnight water meter
Source type
SMART METER / SIMULATED METER
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Data limitation
Site-level monthly data cannot localise the cause to a specific asset.
Baseline window
14-day window
Intervention
Night-flush valve isolated
Measurement window
14-day window
Before
1,960 L/hr overnight
After
410 L/hr overnight
Unit
Water Flow · L/hr
Verification status
VERIFIED
Evidence
Sub-meter SM0881

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 14-day overnight meter window. Demo synthetic. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Overnight residual failed to collapse with occupancy.

  2. 02

    ANALYTICS

    Baseline 1,960 L/hr overnight on SM0881.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Isolation of night-flush valve recommended.

  4. 04

    RECOMMENDATION

    Isolation of night-flush valve recommended.

  5. 05

    APPROVAL

    Facilities approved isolation.

  6. 06

    ACTION

    Valve isolated and tagged.

  7. 07

    MEASUREMENT

    Fourteen-day mean 410 L/hr overnight.

  8. 08

    VERIFICATION

    Avoided overnight volume holds.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
SITE LEVEL
Source ID
SM0881 · Overnight water meter
Source type
SMART METER / SIMULATED METER
Metric
Water Flow · L/hr
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Water Analytics Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Site-level monthly data cannot localise the cause to a specific asset.
  • Additional sub-meter or BMS data is required to identify the responsible asset.
  • Sample stream only. No live BMS or IoT connectivity.

NX-000164

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

LED retrofit, loading bays

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

LED retrofit, loading bays

Dubai South Facility · Lighting circuit LC-12

  1. 01 Before

    41 kWh/night

  2. 02 Action

    LED retrofit, loading bays

  3. 03 After

    18 kWh/night

  4. 04 Verified result

    AED 12,600

Reduction
8,395 kWh avoided · 1.35 tCO₂e avoided
Financial impact
AED 12,600
Evidence
Lighting circuit LC-12
Confidence
97%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Asset
LC-12 — Loading bay lighting LC-12
Source ID
LC-12 · Lighting circuit
Source type
SENSOR / SIMULATED
Data quality
HIGH — SAMPLE
Detection resolution
ASSET / ZONE
Data limitation
Sample stream only. No live BMS or IoT connectivity.
Baseline window
30-day window
Intervention
LED retrofit, loading bays
Measurement window
30-day window
Before
41 kWh/night
After
18 kWh/night
Unit
Demand · kWh/night
Verification status
VERIFIED
Evidence
Lighting circuit LC-12

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 30-day lighting circuit window. Demo synthetic. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency / asset-level M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Loading-bay lighting remaining at occupied output.

  2. 02

    ANALYTICS

    41 kWh/night on LC-12.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. LED retrofit approved as a scheduled works item.

  4. 04

    RECOMMENDATION

    LED retrofit approved as a scheduled works item.

  5. 05

    APPROVAL

    Capex approved.

  6. 06

    ACTION

    Fitting completed.

  7. 07

    MEASUREMENT

    Thirty-day mean 18 kWh/night.

  8. 08

    VERIFICATION

    23 kWh/night avoided holds.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Asset
LC-12 — Loading bay lighting LC-12
Source ID
LC-12 · Lighting circuit
Source type
SENSOR / SIMULATED
Metric
Demand · kWh/night
Data quality
HIGH — SAMPLE
Detection resolution
ASSET / ZONE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Energy Baseline Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

NX-000201

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

AHU-07 unoccupied restore

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

AHU-07 unoccupied restore

JLT Operations Centre · AHU-07 energy channel

  1. 01 Before

    64 kWh overnight

  2. 02 Action

    Unoccupied setback restored

  3. 03 After

    18 kWh overnight

  4. 04 Verified result

    AED 6,900

Reduction
16,820 kWh avoided · 2.70 tCO₂e avoided
Financial impact
AED 6,900
Evidence
AHU-07 energy channel
Confidence
92%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
AHU-07 — AHU-07
Source ID
NEXUS Simulator
Source type
SIMULATOR
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Data limitation
Sample stream only. No live BMS or IoT connectivity.
Baseline window
14-day window
Intervention
Unoccupied setback restored
Measurement window
14-day window
Before
64 kWh overnight
After
18 kWh overnight
Unit
kWh
Verification status
VERIFIED
Evidence
AHU-07 energy channel

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 14-day overnight AHU window. Demo synthetic. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency / asset-level M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    AHU-07 remaining in occupied mode after close.

  2. 02

    ANALYTICS

    64 kWh overnight locked.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Restore weekday unoccupied setback from 20:00 GST.

  4. 04

    RECOMMENDATION

    Restore weekday unoccupied setback from 20:00 GST.

  5. 05

    APPROVAL

    Schedule change approved.

  6. 06

    ACTION

    Setback restored by facilities.

  7. 07

    MEASUREMENT

    Fourteen-day mean 18 kWh overnight.

  8. 08

    VERIFICATION

    Avoided overnight cooling holds.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
AHU-07 — AHU-07
Source ID
NEXUS Simulator
Source type
SIMULATOR
Metric
kWh
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Energy Baseline Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

NX-000218

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Cooling-tower make-up trimmed

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

Cooling-tower make-up trimmed

Business Bay HQ · Make-up meter MU-02

  1. 01 Before

    920 L/hr make-up

  2. 02 Action

    Blowdown setpoint corrected

  3. 03 After

    610 L/hr make-up

  4. 04 Verified result

    AED 11,200

Reduction
671,600 L avoided · 0.23 tCO₂e avoided
Financial impact
AED 11,200
Evidence
Make-up meter MU-02
Confidence
90%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
SITE LEVEL
Source ID
NEXUS Simulator
Source type
SIMULATOR
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Data limitation
Site-level monthly data cannot localise the cause to a specific asset.
Baseline window
21-day window
Intervention
Blowdown setpoint corrected
Measurement window
21-day window
Before
920 L/hr make-up
After
610 L/hr make-up
Unit
L/hr
Verification status
VERIFIED
Evidence
Make-up meter MU-02

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 21-day make-up window. Demo synthetic. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Make-up remaining high after wet-bulb collapse.

  2. 02

    ANALYTICS

    920 L/hr make-up on MU-02.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Blowdown setpoint correction recommended.

  4. 04

    RECOMMENDATION

    Blowdown setpoint correction recommended.

  5. 05

    APPROVAL

    Plant operator approved.

  6. 06

    ACTION

    Setpoint written locally.

  7. 07

    MEASUREMENT

    Twenty-one-day mean 610 L/hr.

  8. 08

    VERIFICATION

    310 L/hr avoided holds.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
SITE LEVEL
Source ID
NEXUS Simulator
Source type
SIMULATOR
Metric
L/hr
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Water Analytics Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Site-level monthly data cannot localise the cause to a specific asset.
  • Additional sub-meter or BMS data is required to identify the responsible asset.
  • Sample stream only. No live BMS or IoT connectivity.

NX-000241

VERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Generator warm-idle ended

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

Generator warm-idle ended

Dubai South Facility · Generator log G-01

  1. 01 Before

    2.4 hours idle / week

  2. 02 Action

    Test window locked to 25 minutes

  3. 03 After

    0.4 hours / week

  4. 04 Verified result

    AED 7,150

Reduction
4.80 tCO₂e avoided
Financial impact
AED 7,150
Evidence
Generator log G-01
Confidence
89%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Asset
GEN-01 — Standby generator G-01
Source ID
NEXUS Simulator
Source type
SIMULATOR
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Data limitation
Sample stream only. No live BMS or IoT connectivity.
Baseline window
28-day window
Intervention
Test window locked to 25 minutes
Measurement window
28-day window
Before
2.4 hours idle / week
After
0.4 hours / week
Unit
hours
Verification status
VERIFIED
Evidence
Generator log G-01

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Annualised from a 28-day runtime log. Grid-mix factor is demo, not a published factor. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency / asset-level M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    G-01 idling outside the authorised test window.

  2. 02

    ANALYTICS

    2.4 hours idle / week.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Lock weekly test to 25 supervised minutes.

  4. 04

    RECOMMENDATION

    Lock weekly test to 25 supervised minutes.

  5. 05

    APPROVAL

    Operations approved.

  6. 06

    ACTION

    Procedure updated.

  7. 07

    MEASUREMENT

    Four-week mean 0.4 hours / week.

  8. 08

    VERIFICATION

    Idle carbon holds as avoided.

  9. 09

    IMPACT RECORD

    Impact record written to the ledger after verification.

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Asset
GEN-01 — Standby generator G-01
Source ID
NEXUS Simulator
Source type
SIMULATOR
Metric
hours
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Derived carbon impact from verified energy and water records
AI role
Interpretation / Prioritisation

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

NX-000176

MEASURINGSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Break-pack bin split

VERIFIED SAMPLE IMPACT

SAMPLE DATAMEASURING

Break-pack bin split

Al Quoz Warehouse · Weighbridge WB-03

  1. 01 Before

    38% contamination

  2. 02 Action

    Break-pack bin split

  3. 03 After

    24% contamination

  4. 04 Verified result

    AED 4,200

Reduction
3.10 tCO₂e avoided
Financial impact
AED 4,200
Evidence
Weighbridge WB-03
Confidence
81%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Al Quoz Warehouse · AQ-WH
Asset
WB-03 — Weighbridge WB-03
Source ID
WB-03 · Weighbridge
Source type
SENSOR / SIMULATED
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Data limitation
Sample stream only. No live BMS or IoT connectivity.
Baseline window
21-day window
Intervention
Break-pack bin split
Measurement window
21-day window
Before
38% contamination
After
24% contamination
Unit
Mass · %
Verification status
MEASURING
Evidence
Weighbridge WB-03

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Measuring. Not included in verified totals. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency / asset-level M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Contamination +19 pts on mixed recyclables.

  2. 02

    ANALYTICS

    38% contamination at WB-03.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Split the break-pack bin pair.

  4. 04

    RECOMMENDATION

    Split the break-pack bin pair.

  5. 05

    APPROVAL

    Warehouse lead approved.

  6. 06

    ACTION

    Bins split.

  7. 07

    MEASUREMENT

    Window still open. 24% so far.

  8. 08

    VERIFICATION

    Not reached

  9. 09

    IMPACT RECORD

    Not reached

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Al Quoz Warehouse · AQ-WH
Asset
WB-03 — Weighbridge WB-03
Source ID
WB-03 · Weighbridge
Source type
SENSOR / SIMULATED
Metric
Mass · %
Data quality
HIGH — SAMPLE
Detection resolution
ASSET
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
NEXUS domain services
AI role
Not commissioned — display only

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

NX-000151

UNVERIFIEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Irrigation schedule tightened

VERIFIED SAMPLE IMPACT

SAMPLE DATAUNVERIFIED

Irrigation schedule tightened

Business Bay HQ · Irrigation controller IC-04

  1. 01 Before

    6,400 L/day landscape

  2. 02 Action

    Irrigation schedule tightened

  3. 03 After

    Pending post-measure

  4. 04 Verified result

    AED —

Reduction
Pending
Financial impact
AED —
Evidence
Irrigation controller IC-04
Confidence
74%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
SITE LEVEL
Source ID
IC-04 · Irrigation controller
Source type
SENSOR / SIMULATED
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Data limitation
Site-level monthly data cannot localise the cause to a specific asset.
Baseline window
7-day window
Intervention
Irrigation schedule tightened
Measurement window
7-day window
Before
6,400 L/day landscape
After
Pending post-measure
Unit
Volume · L/day
Verification status
UNVERIFIED
Evidence
Irrigation controller IC-04

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Unverified. Controller currently offline. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Landscape flow not tracking the dry-bulb drop.

  2. 02

    ANALYTICS

    6,400 L/day landscape.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Tighten night irrigation window.

  4. 04

    RECOMMENDATION

    Tighten night irrigation window.

  5. 05

    APPROVAL

    Not reached

  6. 06

    ACTION

    Not reached

  7. 07

    MEASUREMENT

    Not reached

  8. 08

    VERIFICATION

    Not reached

  9. 09

    IMPACT RECORD

    Not reached

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Business Bay HQ · BB-HQ
Asset
SITE LEVEL
Source ID
IC-04 · Irrigation controller
Source type
SENSOR / SIMULATED
Metric
Volume · L/day
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Water Analytics Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Site-level monthly data cannot localise the cause to a specific asset.
  • Additional sub-meter or BMS data is required to identify the responsible asset.
  • Sample stream only. No live BMS or IoT connectivity.

NX-000140

REJECTEDSAMPLE DATANOT ACTUAL CUSTOMER SAVINGS

Single-use catering swap trial

VERIFIED SAMPLE IMPACT

SAMPLE DATAREJECTED

Single-use catering swap trial

JLT Operations Centre · Procurement log PR-77110

  1. 01 Before

    PET units 4,200/month

  2. 02 Action

    Reusable service trial

  3. 03 After

    No statistically valid window

  4. 04 Verified result

    AED —

Reduction
Insufficient evidence
Financial impact
AED —
Evidence
Procurement log PR-77110
Confidence
41%

NOT ACTUAL CUSTOMER SAVINGS

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
SITE LEVEL
Source ID
NEXUS Simulator
Source type
SIMULATOR
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Data limitation
Site-level monthly data cannot localise the cause to a specific asset.
Baseline window
14-day window
Intervention
Reusable service trial
Measurement window
14-day window
Before
PET units 4,200/month
After
No statistically valid window
Unit
units
Verification status
REJECTED
Evidence
Procurement log PR-77110

Measurement & Verification · IPMVP-aligned workflow · baseline methodology. Rejected. Sample too small for verification. Sample data. Not IPMVP certified. Not a completed third-party verification.

IPMVP-aligned workflow · higher-frequency M&V. Not IPMVP certified.

Evidence journey

  1. 01

    DETECTION

    Single-use PET volume in catering PR.

  2. 02

    ANALYTICS

    4,200 units / month.

  3. 03

    AI INTERPRETATION

    INFIGROWTH AI interpreted the analytics. Reusable trial proposed.

  4. 04

    RECOMMENDATION

    Reusable trial proposed.

  5. 05

    APPROVAL

    Trial approved.

  6. 06

    ACTION

    Trial started.

  7. 07

    MEASUREMENT

    Insufficient observations.

  8. 08

    VERIFICATION

    Not reached

  9. 09

    IMPACT RECORD

    Not reached

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
JLT Operations Centre · JLT-OC
Asset
SITE LEVEL
Source ID
NEXUS Simulator
Source type
SIMULATOR
Metric
units
Data quality
HIGH — SAMPLE
Detection resolution
BUILDING / SITE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
NEXUS domain services
AI role
Not commissioned — display only

Data limitation

  • Site-level monthly data cannot localise the cause to a specific asset.
  • Additional sub-meter or BMS data is required to identify the responsible asset.
  • Sample stream only. No live BMS or IoT connectivity.