WORKING / DEPLOYED
Sample data

Site

Dubai South Facility

Complete facility story: data, analysis, recommended solutions and verified sample impact.

SAMPLE DATA MODE

  1. 01 Data

    What is happening?

  2. 02 Analysis

    What is wrong and why?

  3. 03 Solution

    What should be done?

  4. 04 Impact

    What changed and can we prove it?

All sitesSAMPLE DATAREFERENCE FACILITY

Data context

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Building
DS-FC-MAIN · Facility
Location
Dubai South, Dubai, UAE
Asset
Site register
Data source / Meter
NEXUS Simulator
Metric
Energy · Water
Unit
kW · L/hr
Resolution
Site to asset / zone
Data quality
HIGH — SAMPLE
Integration
Simulated — No live BMS / IoT
Data mode
Sample

DS-FC

REFERENCE FACILITYSAMPLE DATA

Dubai South Facility

Dubai South, Dubai, UAE

Site name
Dubai South Facility
Site ID
DS-FC
Location
Dubai South
Emirate
Dubai
Country
UAE
Premise / facility type
Facility
Building ID
DS-FC-MAIN
Data mode
DEMO
Integration status
SIMULATED — NO LIVE BMS / IOT CONNECTION
Data source
NEXUS Simulator
Data maturity
REAL-TIME SIMULATION
Data quality
HIGH — SAMPLE
Connected assets
2
Connected sources
1
Open opportunities
1
Active interventions
1
Verified sample records
2

A sensor is optional. A traceable data source is mandatory. SIMULATED — NO LIVE BMS / IOT CONNECTION. Future feeds (BACnet · Modbus · MQTT · API · CSV · utility meter feeds — SUPPORTED / PLANNED, not ACTIVE).

Site resource fingerprint

Energy

stable

Water

stable
Open issues
1
Data coverage
HIGH
Sources
1
Resolution
ASSET / ZONE
Verified sample records
2
Verified sample value
AED 19,750
NOT ACTUAL CUSTOMER SAVINGS

Where this data comes from

Data lineage

SAMPLE DATA

Organisation
NEXUS Reference Portfolio
Site
Dubai South Facility · DS-FC
Asset
LC-12 — Loading bay lighting LC-12
Source ID
LC-12 · Lighting circuit
Source type
SENSOR / SIMULATED
Metric
Energy · kWh
Data quality
HIGH — SAMPLE
Detection resolution
ASSET / ZONE
Source
NEXUS Simulator
Stored in
Railway PostgreSQL
Analysis
Energy Baseline Engine
AI role
Interpretation / Prioritisation

Data limitation

  • Sample stream only. No live BMS or IoT connectivity.

Building

DS-FC-MAIN

Facility · Dubai South, Dubai, UAE

Data sources

LC-12

Lighting circuit

Asset LC-12 — Loading bay lighting LC-12 · Zone Loading bay · Demand (kW) · Energy (kWh)

SMART METER / SIMULATED METER · SIMULATED

Assets

GEN-01

Standby generator G-01

Power · Stable · DS-FC-MAIN

LC-12

Loading bay lighting LC-12

Lighting · Verified · DS-FC-MAIN

Metrics

Energy
132 kW
Water
410 L/hr
Open issues
1
Sample ledger value
AED 19,750

NOT ACTUAL CUSTOMER SAVINGS

Open analysis

carbon

Generator warm-idle beyond window

Preview recommendation · AED 7,150 potential · POTENTIAL IMPACT · NOT YET ACHIEVED

Interventions

Ranked operational cases

DERIVEDCARBON IMPACT
Site
Dubai South Facility · DS-FC
Building / asset
GEN-01 — Standby generator G-01
Data source
NEXUS Simulator
Metric
Idle hours · hours
Sample / real status
SAMPLE DATA

Standby generator at Dubai South idling outside the test window.

Confidence
89%
Observed
2.4 hours idle
Expected
0.4 hour test window

DERIVED CARBON IMPACT

Impact / evidence

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

LED retrofit, loading bays

Dubai South Facility · Lighting circuit LC-12

  1. 01 Before

    41 kWh/night

  2. 02 Action

    LED retrofit, loading bays

  3. 03 After

    18 kWh/night

  4. 04 Verified result

    AED 12,600

Reduction
8,395 kWh avoided · 1.35 tCO₂e avoided
Financial impact
AED 12,600
Evidence
Lighting circuit LC-12
Confidence
97%

NOT ACTUAL CUSTOMER SAVINGS

VERIFIED SAMPLE IMPACT

SAMPLE DATAVERIFIED

Generator warm-idle ended

Dubai South Facility · Generator log G-01

  1. 01 Before

    2.4 hours idle / week

  2. 02 Action

    Test window locked to 25 minutes

  3. 03 After

    0.4 hours / week

  4. 04 Verified result

    AED 7,150

Reduction
4.80 tCO₂e avoided
Financial impact
AED 7,150
Evidence
Generator log G-01
Confidence
89%

NOT ACTUAL CUSTOMER SAVINGS